Part # Name Description
ABB OREL-01-KIT Relay Output Extension The Relay Output Extension module offers three (3) Form C relay outputs numbered RO 4, 5 and 6, rated 2 A maximum current. Switching capacity is 6 A (24 VDC resistive), 1500 VA (250 VAC). Each relay is galvanically isolated from each other (2.5 kVAC, 1 minute). Each relay is programmable.
OTAC-01-KIT Pulse Encoder Interface The Pulse Encoder Interface module offers a differential or single ended interface for a digital pulse encoder connection. The module is capable of operating from either a 15 or 24 VDC signal with a maximum frequency of 200kHz.
OHDI-01-KIT 115/230V Digital Input Interface The 115/230V Digital Input Interface module offers six (6) 115V or three (3) 230V rated relays mounted on a common board used to drive DI1 through DI6 of the ACS550. The 115/230V must be provided by the user.
RCNA-01-KIT ControlNet Adapter The ControlNet network use an RG-6 quad shielded cable or fibre with support for media redundancy. The RCNA-01 Adapter module supports only RG-6 quad shielded cable (coax) for the bus connection. ControlNet is flexible in topology options (bus, tree, star) to meet various application needs. The fieldbus speed is 5 Mbits/s. The RCNA-01 ControlNet Adapter module can not originate connections on its own, but a scanner node can open a connection towards it. The ControlNet protocol is implemented
RETA-01-KIT Ethernet Adapter The RETA-01 Adapter module supports the Modbus/TCP and EtherNet/IP network protocols. Modbus/TCP is a variant of the Modbus family of simple, vendor-neutral communication protocols intended for supervision and control of automation equipment. The implementation of the Modbus/TCP server in the RETA-01 module is done according to the Modbus/TCP Specification 1.0. The Modbus/TCP protocol allows the RETA-01 module to be used as an Ethernet bridge to control the drive. The RETA-01 module supports eig
RECA-01-KIT EtherCAT Adapter The adapter module supports the CANopen DSP 402 (Device Profile Drives and Motion Control) profile or the ABB Drives profile. The RECA-01 implements the EtherCAT state machine, four sync manager channels to control the access to the application memory, two watch dogs and specified EtherCAT services, addressing modes and FMMUs.
RCAN-01-KIT CANopen Adapter CANopen is a higher layer protocol based on the CAN (Control Area Network) serial bus system and the CAL (CAN Application Layer). CANopen assumes that the hardware of the connected device has a CAN transceiver and a CAN controller as specified in ISO 11898. The CANopen Communication Profile, CiA DS 301, includes both cyclic and event driven communication, which makes it possible to reduce the bus load to minimum while still maintaining extremely short reaction times. High communication performan
RETA-02-KIT PROFINET IO Adapter The RETA-02 module supports both Modbus/TCP and PROFINET IO network protocols. Modbus/TCP is a variant of the Modbus family of simple, vendor neutral communication protocols intended for supervision and control of automation equipment. PROFINET IO is an open standard for industrial Ethernet, intended for configuration, supervision and control of automation equipment. The RETA-02 supports 10/100 Mbps transfer rate w network connections made with CAT 5 wiring and RJ-45 connectors. Both star and bu
SREA-01-KIT Ethernet Adapter SREA-01 is an optional device for web browser based remote interface to the ACS350, ASC550 and ACS800 drives via Ethernet. This din rail mounted adapter enables remote data acquisition through a standard web browser, utilizing an internal web server for drive configuration and access. Multiple drives (up to 10) can be connected to the Modbus-RTU network through the drive’s Modbus-RTU port. The ASC350 and ACS550 can also be connected through the control panel port, although an additional RS-485 c
ABB ACS-CP-A Control Panel (Spare/additional) The Advanced Control Panel is supplied with the ACS%%) drive as standard. To obtain additional control panels, specify this option.
ABB OPMP-01 Cabinet Panel Mounting Control Panel Mounting Platform allows remote mounting of the keypad on a large enclosure or remote panel. The kit maintains UL Type 12 integrity of the mounting location. Adapters, 3 m (10ft) cable and mounting hardware are included in this kit. With this mounting arrangement, the keypad is removable from the panel in a fashion identical to a drive-mounted keypad.
ABB OFAN-R1 Preventative Maintenance Fan Kit Frame Size R1
ABB OFAN-R2 Preventative Maintenance Fan Kit Frame Size R2
OFAN-R3 Preventative Maintenance Fan Kit Frame size R3
OFAN-R4 Preventative Maintenance Fan Kit Frame Size R4
OFAN-R5 Preventative Maintenance Fan Kit Frame Size R5
OFAN-R6 Preventative Maintenance Fan Kit Frame Size R6
ABB 3AFE64532871 DriveWindow Light DriveWindow Light is software designed for online drive commissioning and maintenance purposes. It is possible to adjust parameters, read the actual values and control the drive with DriveWindow Light instead of the drive control panel. It is also possible to follow trends and draw graphs. An RJ45 to DB9 adapter cable is provided to permit connection between the panel port and a Personal Computer. Limited Legacy support is offered for ACS140, ACS400 and DCS400 products, and requires the use of a
3AUA0000041141 DriveBrowser DriveBrowser software is designed for online drive commissioning and maintenance purposes. DriveBrowser uses a computer’s standard Ethernet port to connect to an EtherNet/IP or Modbus-TCP network. It is compatible with the ACS350, ACS550, ACH550 and ACS800* drives (*ACS800 standard control program). Drives require configuration and connection to an EtherNet/IP or Modbus-TCP network. DriveBrowser supports Microsoft Windows operating systems (Windows NT4, 2000, XP & Vista). Configure network conne
SECG-01 Ethernet to ControlNet Gateway SECG-01 (EtherNet/IP to ControlNet) – will allow a DriveBrowser user to connect a PC’s Ethernet port to drives on a ControlNet networks.
SEDG-01 Ethernet to DeviceNet Gateway SEDG-01 (EtherNet/IP to DeviceNet) – will allow a DriveBrowser user to connect a PC’s Ethernet port to drives on a DeviceNet networks.
MFDT-01 FlashDrop FlashDrop is a powerful palm sized tool for fast and easy parameter selecting and setting. It gives the possibility to hide selected parameters to protect the machine. Only the parameters needed in the application are shown. The tool can copy parameters needed in the application are shown. The tool can copy parameters between a PC and a drive. Includes DrivePM (Drive Parameter Manager) which is a software tool to create, edit, and copy parameter sets for FlashDrop. The parameter sets can consist
ABB OPCA-01 RJ45/DB9 Adapter This adapter converts the drive’s panel port RJ45 (CAT 5 cable connector) plug to a 9 pin RS-232 computer serial port connector for connecting the ACS550 to a Personal Computer.
OCAT-01 Panel Extension Cable 7 foot CAT 5 patch cable allows remote operation of the standard panel or connection of the drive to a personal computer using the RJ45/DB9 Adapter which must be purchased separately.
ACS/H-CP-EXT Control Panel Mounting Control Panel Mounting Kit for ACS550 drives allows remote mounting of the ACS550 keypad on the door of an enclosure. The kit includes a 10 ft (3m) CAT 5 patch cable, gasket for NEMA 12, mounting hardware and drilling template.
FMK-A-R1 Flange Mounting Kits for Frame Size R1 Flange Mounting Kit for the ACS550 drives allows mounting the drive with the heatsink external to a 3rd party enclosure. Use of the flange kit requires removal of the drive cover, reducing protection to IP00.
FMK-A-R2 Flange Mounting Kits Frame Size R2 Flange Mounting Kit for the ACS550 drives allows mounting the drive with the heatsink external to a 3rd party enclosure. Use of the flange kit requires removal of the drive cover, reducing protection to IP00.
FMK-A-R3 Flange Mounting Kit Frame Size R3 Flange Mounting Kit for the ACS550 drives allows mounting the drive with the heatsink external to a 3rd party enclosure. Use of the flange kit requires removal of the drive cover, reducing protection to IP00.
FMK-A-R4 Flange Mounting Kit Frame Size 4 Flange Mounting Kit for the ACS550 drives allows mounting the drive with the heatsink external to a 3rd party enclosure. Use of the flange kit requires removal of the drive cover, reducing protection to IP00.
AC8-FLNGMT-R5 Flange Mounting Kits Frame Size R5 Flange Mounting Kit for the ACS550 drives allows mounting the drive with the heatsink external to a 3rd party enclosure. Use of the flange kit requires removal of the drive cover, reducing protection to IP00.
AC8-FLNGMT-R6 Flange Mounting Kits Frame Size R6 Flange Mounting Kit for the ACS550 drives allows mounting the drive with the heatsink external to a 3rd party enclosure. Use of the flange kit requires removal of the drive cover, reducing protection to IP00.
ACS/H-CP-EXT-IP66 NEMA 4X Cabinet Panel Mounting Allows remote mounting of the ACS-CP-X Operator Panels on a larger NEMA 4X (IP66) enclosure or remote panel. The kit maintains NEMA 4X integrity of the mounting location. All necessary hardware and a mounting template are provided in addition to a 3 m panel cable. When mounted, the operator is not removable from the front of the enclosure. The operator panel must be purchased separately.